Read NCA's Statement on COVID-19

Perf Weeping Tile 4" x 100'

Polytubes
#PERFWEEP4100

Polytubes Perforated Corrugated High Density Polyethylene Tubing For Subdrainage Applications. Weeping tile is a porus pipe that is used for underground drainage.

  • The Tubing is corrugated for maximum strength, yet it is light in weight and flexible for ease of handling and installation.It can be cut to size on the spot for a custom fit every time.
  • Once installed, it resists both corrosion and abrasion in most applications for dependable performance.
  • The corrugated design adds strength to resists the pressure of burial in the ground. Extra durability is provided by the material itself. The plastic is inert so it is practically indestructible, even in corrosive environments.
  • Tubing is available as standard non-perforated pipes, perforated pipes and perforated pipes with SOCK filter for areas where fine soils present a clogging problem.

Easy to Install: Lightweight and easy to carry. Saves time and labor.No special tools or fittings required, just cut to the required length.

Flexible: Shifts with the ground. No problems due to misalignment and clogging, because the tubing is so flexible. Big 'O' aligns itself which allows the system to continue to work efficiently

Strong-Tough-Durable: Won't crack or break under normal handling and installation procedures. Tough enough to withstand the heaviest loads.

Long Life: Will not deteriorate. Rust resistant. Not affected by acid soil content or other problem soils. Not affected by the freeze-thaw cycle.

The light weight and ease of handling and installation allows this tubing to be ideal for many applications including:

  • Underslab drainage
  • Downspout runoff
  • Interceptor drains
  • Retaining walls
  • Low spots 
  • Pool drains
  • Many more applications 

Proper drainage is essential for successful landscaping, and a properly designed and installed Big 'O' drainage system helps ensure maximum use of the area by removing excess water and promoting overall heath of turf, trees and plants.

Low Spots: For wet spots in the lawn or other areas, use Perforated tubing installed in gravel to pick up the water and carry it to a catch basin or other disposal area. in heavy clay soils, several lines of perforated tubing may be needed to speed drainage.

Foundation Drains: Wet basements are generally caused by ground water being either adjacent to or higher than the basement floor. To prevent the water from entering either the basement wall or at the footings, install perforated tubing in a gravel envelope completely around the house. The bottom of the line should be as low as the bottom of the wall or footing course, with a minimum slope. It should run to a storm sewer or other disposal area. Although the tubing will bend around corners, a 90 degree Elbow is recommended. Also, a big "T" will tie together the ends of the foundation drain at the line leading to the disposal area.

  1. Care during Installation: Care should be taken to prevent damage to the tubing during the backfilling operation. Avoid dropping large soil clods or rocks directly on the tubing. Heavy loads of all types should be avoided until the soil around the installation area is properly settled.
  2. Bedding: Tubing should be bedded in gravel or crushed stone. However, selected soil backfill material may also be used with satisfactory results. The bedding material should be placed around the tubing to a depth of at least 2" (50 mm) over the top of the tubing. When selected soil bedding material from the trench excavation is used, choose small loose particles of soil that will flow around the tubing and minimize soil settling. Avoid large rocks that may damage the tubing or large clods of soil that cause voids and subsequent excessive settling.
  3. Depth To Cover: If vehicular traffic is expected over tubing, there should be a minimum of 12" (305 mm) of cover over tubing if gravel bedding material is used, Typical recommended gravel material would be pea gravel, granular A stone or pit run course sand and gravel mixes.
  4. Proper Grades: The grade, or fall on which the tubing is laid is important in that reversals in grade will reduce the effectiveness of the system. Best drainage results are achieved with a continuous downhill fall, or grade, over the entire length of the drain line. A fall of 2" (50 mm) per 100ft (30.5m)of length is generally considered adequate, Greater fall will promote more rapid drainage.
  5. Proper Backfill Selection: Choose your materials according to application. If absorption and drainage are required, perforated tubing should be used. If tubing serves only to remove water away from an area ( such as downspout runoffs, etc.), non-perforated tubing is best because it will not dissipate water into the surrounding area. Non-perforated tubing should also be used if the line runs close to trees where root penetration may be a problem. If the soil being drained is sandy or silty, the Big 'O' "The Sock" filter should be used to prevent fines from entering and blocking the drainage line.

Tubing is manufactured from high density polyethylene resin which meets or exceeds the requirements of Type III, Category 4 or 5, Grade P33 or P34, Class C, as per ASTM D1248.

The nominal size of the pipe is based on the nominal inside diameter of the pipe. the tolerance on the specified inside diameter shall be +/-3%.

  • Nominal Diameter: 4" (100 mm) and 6" (150 mm)
  • Outside Diameter: 5" (120 mm) and 7" (180 mm)
Keep up to date with NCA!

Not Finding What You're Looking For?
Try browsing our catalogues

BROWSE OUR CATALOGUE